UltraDry EDS Detector

The Thermo Scientific* UltraDry X-ray detector provides superior resolution at incredibly high collection rates.
The Thermo Scientific UltraDry silicon drift X-ray detector, a best-in-class instrument offering faster, more accurate interpretation of X-rays for industries such as metals and mining, advanced materials and semiconductors. The new detector further improves the performance of the Thermo Scientific NORAN System 7 X-ray Microanalysis System.
 
 
 
 
Part Number Description   Quantity
IQLAADGABKFABSMANG UltraDry EDS Detector
Request Quote
Please Note: Availability may vary by country.  
 
Best-in-Class Detector Size, Speed of Analysis and Resolution

  • Advanced field-effect transistor (FET) integration and a proprietary preamplifier stage create the extraordinary operating space that enables the superior performance of the UltraDry detector
  • With a smaller and integrated FET, the device capacitance that leads to electronic noise is virtually eliminated
  • By optimizing and characterizing the detector electronics, pulse pile-up and sum peaks are effectively handled;dead time is minimized and resolution is maximized on the fly across a wide range of operating conditions
  • The UltraDry EDS detector results in an extremely high data collection rate with no external or liquid nitrogen cooling and virtually no sacrifice in energy resolution
  • The unique-to-Thermo slotted collimator design allows for consistent collection rates across the widest possible range of working distances, which is absolutely critical to dual EDS and EBSD acquisition
  • The offered range of crystal active areas (10mm2, 30mm2, 60mm2, 100mm2) and the smallest in class packaging envelope provides the greatest solid angle of collection available for a detector on the market today
  • FWHM measured (ISO 15632) at 5.89keV (Mn-Ka) with 10,000 counts per second stored in the spectra, measured on the electron microscope
  • WD range is measured by varying the vertical distance between the pole piece and the surface of the sample and measuring the input count. STD distance of 50mm. TOA of 35°. The range is defined as within 25% of the peak count rate at the optimized working distance.
  • Vertically slotted collimator to enable maximum WD range. Absolute requirement for dual EDS/EBSD acquisition mode.
  • Light element sensitivity down to beryllium
  • No auxiliary cooling connections, water or fans. No liquid nitrogen.
  • Operating environment to 35 °C
  • ±5 eV resolution change (±3eV typical between 1% and 60%dead time) from minimum to maximum count rate at a givenanalyzer time constant
  • ±5eV peak shift (±3eV typical between 1% and 60% deadtime) from minimum to maximum count rate at a given analyzertime constant
  • Input count rates >1,000,000 counts per second
  • Motorized slide optionally available

 
 
 
 
 
Help image

Need Help?


Have a Question?
We're here to help you.

Select Country for Contact Info This website provides global contact information for our products and services. When you select a Contact Country, the contact information that is displayed by default will be for this country.



  • Sales
 
  Service Note:See the Related Services tab for Service Forms.

NewsView more »

Driving Bold Progress in Materials Analysis

Driving Bold Progress in Materials Analysis Analyze your materials faster and better with our range of Microanalysis and Surface Analysis instruments. To download our latest application notes or reque...

EventsView more »

Molecular Spectroscopy, Surface Analysis and Microanalysis Events

Join us at any of the tradeshows and conferences listed here to chat one-on-one with Application Specialists or Sales Rep in finding the right Thermo Scientific instrument for your analytical needs.

Microanalysis Webinars

Join us for one-hour-or-less, complimentary webinars on varying Microanalysis applications.

uspgh-zcom-p2-leg6.fishersci.com:80