Duke Standards* 4000 Series Monosized Particles

Thermo Scientific* Duke Standards* 4000 Series Monosized Particles are excellent for use with any application that requires a NIST* traceable size standard with a very narrow standard deviation.
Particle spheres are used instead of irregularly shaped particles to minimize the response of analytical systems to shape effects. Particles from 1 to 160µm are packaged as aqueous suspensions in 15mL dropper-tipped bottles, at an optimum concentration for dispersion, handling and dilution. Diameters of 200µm and larger are packaged as dry sphere particles.
 
 
 
 
Part Number Description   Quantity
4009A Dia.: 0.994µm ± 0.010µm, σ = 0.010µm, 1.0% CV
Request Quote
4010A Dia.: 1.019µm ± 0.015µm, σ = 0.010µm, 1.0% CV
Request Quote
4011A Dia.: 1.101µm ± 0.017µm, σ = 0.012µm, 1.1% CV
Request Quote
4013A Dia.: 1.361µm ± 0.015µm, σ = 0.021µm, 1.5% CV
Request Quote
4016A Dia.: 1.587µm ± 0.018µm, σ = 0.021µm, 1.3% CV
Request Quote
4018A Dia.: 1.745µm ± 0.022µm, σ = 0.019µm, 1.1% CV
Request Quote
4202A Dia.: 1.999µm ± 0.020µm, σ = 0.022µm, 1.1% CV
Request Quote
4025A Dia.: 2.504µm ± 0.027µm, σ = 0.025µm, 1.0% CV
Request Quote
4203A Dia.: 3.002µm ± 0.019µm, σ = 0.029µm, 1.1% CV
Request Quote
4204A Dia.: 4.000µm ± 0.043µm, σ = 0.04µm, 1.0% CV
Request Quote
4205A Dia.: 4.993µm ± 0.040µm, σ = 0.05µm, 1.0% CV
Request Quote
4206A Dia.: 6.007µm ± 0.040µm, σ = 0.06µm, 1.0% CV
Request Quote
4207A Dia.: 6.982µm ± 0.045µm, σ = 0.07µm, 1.0% CV
Request Quote
4208A Dia.: 7.979µm ± 0.075µm, σ = 0.09µm, 1.1% CV
Request Quote
4209A Dia.: 8.956µm ± 0.082µm, σ = 0.09µm, 1.0% CV
Request Quote
4210A Dia.: 10.00µm ± 0.08µm, σ = 0.09µm, 0.9% CV
Request Quote
4212A Dia.: 12.01µm ± 0.11µm, σ = 0.12µm, 1.0% CV
Request Quote
4215A Dia.: 14.97µm ± 0.10µm, σ = 0.13µm, 0.9% CV
Request Quote
4220A Dia.: 19.99µm ± 0.25µm, σ = 0.28µm, 1.4% CV
Request Quote
4225A Dia.: 24.61µm ± 0.22µm, σ = 0.27µm, 1.1% CV
Request Quote
4230A Dia.: 29.75µm ± 0.56µm, σ = 0.42µm, 1.4% CV
Request Quote
4240A Dia.: 39.94µm ± 0.35µm, σ = 0.52µm, 1.3% CV
Request Quote
4250A Dia.: 50.2µm ± 0.3µm, σ = 0.5µm, 1.0% CV
Request Quote
4260A Dia.: 59.2µm ± 0.6µm, σ = 0.8µm, 1.4% CV
Request Quote
4270A Dia.: 69.1µm ± 0.9µm, σ = 0.8µm, 1.2% CV
Request Quote
4280A Dia.: 79.0µm ± 1.3µm, σ = 1.0µm, 1.3% CV
Request Quote
4310A Dia.: 100µm ± 1.5µm, σ = 1.6µm, 1.6% CV
Request Quote
4311A Dia.: 113µm ± 1.0µm, σ = 1.6µm, 1.4% CV
Request Quote
4314A Dia.: 138µm ± 2.0µm, σ = 2.2µm, 1.6% CV
Request Quote
4316A Dia.: 160µm ± 3.1µm, σ = 2.9µm, 1.8% CV
Request Quote
4320A Dia.: 197µm ± 3.2µm, σ = 5.7µm, 2.9% CV
Request Quote
4324A Dia.: 235µm ± 3.7µm, σ = 7.3µm, 3.1% CV
Request Quote
4328A Dia.: 279µm ± 4.9µm, σ = 13.5µm, 4.8% CV
Request Quote
4330A Dia.: 289µm ± 6.2µm, σ = 9.7µm, 3.4% CV
Request Quote
4340A Dia.: 399µm ± 8.5µm, σ = 12.2µm, 3.1% CV
Request Quote
4350A Dia.: 500µm ± 10µm, σ = 25.1µm, 5.0% CV
Request Quote
4355A Dia.: 552µm ± 11µm, σ = 27.0µm, 4.9% CV
Request Quote
4365A Dia.: 644µm ± 11µm, σ = 24.8µm, 3.9% CV
Request Quote
4375A Dia.: 773µm ± 13µm, σ = 33.3µm, 4.3% CV
Request Quote
4400A Dia.: 1007µm ± 13µm, σ = 48.3µm, 4.8% CV
Request Quote
Please Note: Availability may vary by country. Show All
 
Each package of standards contains a Certificate of Calibration and Traceability to NIST which includes a description of the calibration method and its uncertainty, and a table of chemical and physical properties. A Material Safety Data Sheet, with handling and disposal instructions, is also included. Packages are lot-numbered for convenient technical service and support after the sale.

Thermo Fisher Scientific has its own engineering, production and metrology facilities for better quality control and response to customer needs. In addition to this line of polymer size standards, we also offer calibration standards in silica and glass materials. Ask our technical service department for information about specific applications or other product needs not listed here.


  • Mean diameters of these particles have been calibrated with Thermo Fisher Scientific's NIST traceable microscopy methods
  • Size distribution and uniformity are measured by electrical resistance analysis or optical microscopy
  • 4000 Series particles from 1 to 160µm are made from polystyrene (PS)
  • 4000 Series particles from 200 to 1000µm are made from polystyrene crosslinked with divinylbenzene (PSDVB)

Ordering Alerts: Products from 1 to 160µm are packaged as aqueous suspensions in 15mL dropper-tipped bottles, at an optimum concentration for dispersion, handling and dilution. Diameters of 200µm and larger are packaged as dry spheres. Packages are lot-numbered for convenient technical service and support after the sale.

Storage Conditions: Store at room temperature or keep refrigerated. Keep bottle tightly sealed to avoid contamination.
Includes: Certificate of Calibration and Traceability to NIST which includes a description of the calibration method and its uncertainty; Table of chemical and physical properties; Material Safety Data Sheet

Certifications: NIST traceable

 
 
 
 
 
Help image

Need Help?


Have a Question?
We're here to help you.

Select Country for Contact Info This website provides global contact information for our products and services. When you select a Contact Country, the contact information that is displayed by default will be for this country.



  • Sales
  • Service
 

Items of InterestView more »

The Sphere "Articles About Particles" eNewsletter

The Sphere is a quarterly Particle Technology e-Newsletter from Thermo Fisher Scientific

uspgh-zcom-p2-leg6.fishersci.com:80