false
ThermoScientific
-1
 

Harshaw TLD* Model 5500 Readers

Thermo Scientific Harshaw 5500 TLD reader provides cost-effective measurements of the radiation dose absorbed by individual TLD elements.
For automatic processing of up to 50 TLD dosimeter elements in a single loading.
Products on this page may include voltages not considered standard in North America. Please review carefully.
 
 
 
 
Part Number Description   Quantity
5500READERMA Model 5500 TLD reader instrument (Macro pick version)
Request Quote
5500TLD-DS3 3 year extended depot service warranty
Request Quote
Harshaw TLD 5500 Model 5500 TLD reader instrument
Request Quote
Please Note: Availability may vary by country.  
 
Compact, attractive reader has a linear, programmable heating system and a cooled photomultiplier tube with associated electronics to measure the TL light output. The WinREMS Software, which runs on a separate computer, provides the user interface, the reader control and the applications software.

  • Easy operation, service and maintenance
  • Measurement quality assurance
  • Unattended automatic operation for up to 50 dosimeters
  • Thermoelectric PMT cooler for maximum gain stability
  • Unattended automatic background subtraction capability
  • Multiple, programmable, linear time-temperature profiles; heating profile includes pre-heat, acquire and anneal cycles
  • Linear contactless hot gas heating with temperature capability up to 600°C (1112°F)
  • Seven decade dynamic acquisition ranges
  • 30 sec. cycle time per chip with normal TTP
  • Withstands 20mm drop on to concrete surface
  • Maintains specifications while exposed to light up to 1000 lux with cover in place
  • Options include glow curve deconvolution software, neutral density filters, and calibration software
Dosimetry Performance When Using LiF:Mg,Ti Chips (TLD-100):

  • Tissue equivalence: Nearly tissue equivalent
  • Batch uniformity: ±15% standard deviation from the batch mean, tighter on special request
  • Residual TL signal: <0.2% of reading, over the range, without annealing
  • Reuse: more than 500 per dosimeter with <10% sensitivity charge
  • Threshold: <10 µGy (1 mrad) based on 2.26 standard deviation of 10 repeat readings of an unexposed dosimeter

Light Detection System

  • Dynamic range: 7 decades
  • Warmup time: 30 min.
  • Linearity: <1% deviation
  • Stability: <1.0 mGy standard deviation of 10 consecutive readings
  • Dark current: <50 mGy 137Cs equivalent
  • Test light: temperature-stabilized LED
  • Stability: <0.5% standard deviation of 10 consecutive readings
  • Color: blue (wavelength 470 nm)

Dosimeter Heating System

  • Method: linear hot nitrogen gas
  • Time/Temperature Profile (TTP) temperature reproducibility: (±1°C)

Ordering Alerts: Computer requirements (minimum): Intel* Pentium*-compatible PC, 120MHz; 64MB RAM; 4GB hard drive; VGA color monitor, 800 x 600 resolution minimum; Mouse and keyboard; CD-ROM drive; One RS232 serial port for connection to Model 5500; One parallel port for printer; Windows* operating system
Includes: automatic sample changer and carrier disk

Recommended for:
  • Radiotherapy planning verification
  • Radiation hardness verification
  • Total body irradiation dose verification
  • Skin irradiation dose verification
  • Stereotactic beam output factor measurement
  • Critical organ dose verification
  • Diagnostic dose studies
  • CT dose measurement for quality assurance
  • Environmental dosimetry
  • Testing for irradiated food
  • Radioactive dating
  • Mammography

 
 
 
 
 
Help image

Need Help?


Have a Question?
We're here to help you.

Select Country for Contact Info This website provides global contact information for our products and services. When you select a Contact Country, the contact information that is displayed by default will be for this country.



  • Sales