Accela is designed to optimize performance of sub-two micron particle columns, providing seamless operation from conventional LC pressures up to 1250 bar for U-HPLC separations of complex matrices.
- Rapid gradient formation with extremely low delay volumes
- Maximum application flexibility with HPLC/U-HPLC in a single system
- Precise flow and gradients with proprietary Force Feedback Control (FFC) technology
- Streamlined integration across a full range of LC & MS detectors
Accela 1250 Pump- Accelerated method development time with quaternary solvent delivery
- HPLC & U-HPLC applications up to 1250 bar
- Extremely fast cycle with a 70µL delay volume
- FFC technology ensures consistent baseline reproducibility
Accela 600 Pump
- Accelerated method development time with quaternary solvent delivery
- Greater application flexibility with flow rates up to 5mL/min at 600 bar
- Minimum gradient equilibration time with a 90µL delay volume
- FFC technology eliminates the need for pulse dampeners and reduces maintenance costs
Accela Open Autosampler
- Maximum flexibility with unmatched reliability and robustness
- Customizable temperature controlled sample formats
- Integrated Dynamic Load and Wash capability resulting in extremely low carryover (0.003% chlorhexidine)
- Saves precious bench space with a customizable open frame architecture in a stackable design
Accela Autosampler
- Optimized for high-throughput applications and sub two micron column particles
- Maximum reproducibility with isothermal injection and separation
- Greater application flexibility with multiple sample formats
- Superior robustness with a diamond coated high pressure valve Accela Photo Diode Array Detector
- Highest detection sensitivity with proprietary LightPipe technology
- Designed for U-HPLC separations with a 1cm path length, 2µL LightPipe flowcell
- Maximum peak resolution with fiberoptic beam shaper
- Easy maintenance with integrated wavelength validation
Accela Photo Diode Array Detector
- Highest detection sensitivity with proprietary LightPipe technology
- Designed for U-HPLC separations with a 1cm path length, 2µL LightPipe flowcell
- Maximum peak resolution with fiberoptic beam shaper
- Easy maintenance with integrated wavelength validation
Accela UV/Vis Detector
- Unlimited applications flexibility with externally mounted flow cells
- Simultaneous detection at two selectable wavelengths in the UV or the visible range of the spectrum
- Instrument versatility with two analog outputs
- Simple maintenance with pre-aligned deuterium and tungsten lamps
Accela Refractive Index (RI) Detector
- High sensitivity HPLC detection
- Faster throughput with a low delay volume flowcell
- Automatic lamp brightness compensation for flowcell stains
- Optimum sensitivity and selectivity with Thermo Scientific columns
Compatible with: Thermo Scientific Mass Spectrometers, Thermo Scientific Hypersil GOLD* HPLC columns, ChromQuest CDS, Xcalibur* MS, Atlas* client/server CDS
Recommended for: Forensics, Pharmaceutical, Biodiesel Analysis, Food Safety, Environmental, Forensics, Evidence Analysis, Drug Screening, Metabolite Analysis