DFS™ High Resolution GC/MS Mass System

Achieve outstanding sensitivity for analysis of POPs with the Thermo Scientific™ DFS™ High Resolution GC/MS System. The DFS double-focusing system is the highest performance mass spectrometer ever built for target compound analysis. Injecting as little as 20fg of TCDD onto the column will give an exceptional signal/noise ratio (greater than 200:1). A product of 50 years of experience in developing magnetic sector MS, the DFS system has all the performance you need in a package that will fit in a small laboratory.

Contact Us About This Product
Catalog #
Sensitivity
Quantity
IQLAAEGAALFABKMAEG
>200:1 for 20

Full specifications
Mass Range 2 to 6000 d
MS Scan Power 0.1 to 10000 Da/sec.
Mass Accuracy <2ppm
Sensitivity >200:1 for 20
Resolution >60,000amu
Voltage 230V
Modes Full range of ionization modes available: EI, CI, FAB, FD/FI
Item Description DFS high resolution GC/MS; Configurable

Please add a quantity

    Please wait, while adding to cart

    Invalid Catalog Number, try after few minutes

    Unable to connect to commerce server, try after a few

    Product Description

    Operation as Simple and Straightforward as a Typical Benchtop MS

    • Automatic tuning
    • Automatic universal mass calibration: Field-based calibration, i.e. mass calibration is independent of scan speed, polarity, ionization mode
    • Unattended automatic operation
    • Intuitive user interface and set-up
    • Comprehensive and flexible data evaluation and reporting
    Outstanding Sensitivity and Specificity with High-throughput
    • Exceptional S/N ratio with extraordinarily low limit of detection: 20fg TCDD on-column in high resolution MID mode gives S/N 200:1
    • Detection system with ±20kV conversion dynode and long-life secondary electron multiplier for efficient detection of ions
    • Low limits of quantitation
    • Mass range of 2-6000Da
    Ease of Ownership
    • Fits into a small laboratory
    • Reduced power consumption
    • Quieter than many other instruments
    • Requires little installation time
    • Immediately productive
    Other Key Features
    • Full range of ionization modes available: EI, CI, FAB, FD/FI
    • Pneumatically actuated exchange lock for ventless exchange of ionization volumes
    • Removable ion volumes for easy source maintenance
    • Radially laminated magnet
    • High performance toroidal ESA
    Recommended For:
    • EI/CI
    • Positive and negative ions
    • Solids probe
    • FAB
    • Other ionization and inlet techniques

    Read More...

    Mass Spectrometry Breakthroughs Launched at ASMS

    Dr. Martin Hornshaw describes Thermo Scientific brand mass spectrometers introduced at ASMS 2011, including new Orbitrap technology. Learn about the Orbitrap Elite, Q Exactive, and how we continue to deliver industry leading solutions.

    Tradeshow video duration: 3 minutes

    Persistent Organic Pollutants (POPs) Center of Excellence

    Discover how effective screening can be utilized in the POPs workflow to allow more time and instrument resources to focus on non-compliant samples. The POPs Center of Excellence serves as a customer reference for resources as well as a partner to laboratories working to improve POPs analysis. 

     

    Webinar

    Implement High Quality, Routine GC-MS/MS Multi-Residue Pesticides Analysis with Ease

    Date: Thursday, March 21, 2013
    Time: 10 am GMT | 11 am CET

    Showing of resources

    No Resources Found

    • All Resources ()

    tab 4