LTQ XL™ Linear Ion Trap Mass Spectrometer

Deliver more structural information than any other ion trap mass spectrometer. The Thermo Scientific™ LTQ XL™  Linear Ion Trap Mass Spectrometer is the only mass spectrometer that offers multiple dissociation techniques, PQD, ETD and CID. Pulsed Q Collision Induced Dissociation (PQD™) is a proprietary technique that eliminates the low mass cut-off concern inherent with all ion traps. This results in extensive coverage for predicted and unpredicted metabolites, and the ability to perform peptide quantification using iTRAQ™ labels.

Contact Us About This Product
Catalog #
Item Description
Quantity
IQLAAEGAAVFACZMAIK
LTQ XL linear ion trap mass spectrometer

Full specifications
Mass Range 15 to 200m/z
Resolution 0.3 FWHM
Amperage 15A
Hertz 50/60Hz
Voltage 230VAC
Weight (Metric) 120kg
Atmospheric Pressure Chemical Electrospray Ionization (APCI) – A loop injection of 2µL of a 125fg/µL solution of reserpine (250 femtograms total sample) at a flow of 400µL/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 to 615.
Item Description LTQ XL linear ion trap mass spectrometer

Please add a quantity

    Please wait, while adding to cart

    Invalid Catalog Number, try after few minutes

    Unable to connect to commerce server, try after a few

    Product Description

    The LTQ XL extends the legendary MSn performance of the LTQ, incorporating more techniques to generate structural information through innovations in Thermo Scientific ion trap technology.

    • Unparalleled sensitivity and unmatched MSn spectral quality
    • Pulsed Q Dissociation (PQD) for generating more fragments and extending the low mass range
    • Electron Transfer Dissociation (ETD) option provides sequence information not available from conventional methods
    • High Resolution Isolation (HRI) enables isolation of isobaric mass peaks for cleaner MSn spectra
    • Ultra-fast polarity switching for high sensitivity analysis of unknowns
    • Automated Data Dependent neutral loss for PTM and biotransformation analyses
    • Excellent charge state determinations with Ultra ZoomScan™
    • Upgradeable to LTQ Orbitrap XL accurate mass technology

    Compatible with:

    • Accela High-Speed LC System (IQLAAAGABHFAAAMAAG)
    • Surveyor Plus HPLC System (IQLAAAGAAOFAFHMALP)
    • LTQ FT Ultra Hybrid Mass Spectrometer (IQLAAEGAAPFADAMAII)
    • LTQ Orbitrap Hybrid Mass Spectrometers ( IQLAAEGAAPFADBMAIJ)
    • ETD Fragmentation, Electron Transfer Dissociation (IQLAAEGABBFACCMAFJ) LCquan 2.5.5 ( SID-LCQUAN25)
    • Mass Frontier Spectral Interpretation Software (IQLAAEGABOFAGUMZZZ) MetWorks Automated Metabolite Identification Software (IQLAAEGABOFAGTMZZZ) PEAKS Studio 4.0 (SID-PEAKS40) ProMass Deconvolution 2.5 (OPTON-20875)
    • Pulsed-Q Dissociation (PQD) (IQLAAEGABBFAGQMZZZ)
    • SIEVE Automated Label-Free Differential Expression Software (INQSOF012/IQLAAEGABSFAHSMAPV)

    Recommended for:

    • Protein identification and quantitative differential expression analysis
    • Biomarker studies and PTM identification
    • Metabolite identification and quantification
    • Tissue imaging
    • High-speed LC methods

    Hardware Features

    Ion Max™ API Source

     

    • Enhanced sensitivity and ruggedness
    •  

    • Sweep Gas™ reduces chemical noise
    •  

    • 60° interchangeable ion probe orientation
    •  

    • Removable metal ion capillary tube provides vent-free maintenance
    Transfer Ion Optics

     

    • Advanced ion guides
    •  

    • High stability and ion transmission efficiency
    2D Linear Quadrupole Ion Trap Mass Spectrometer

     

    • Optimized analyzer dimensions
    •  

    • Regulated helium flow for stable performance
    •  

    • Automatic system calibration
    •  

    • High-efficiency radial ion ejection
    Vacuum System

     

    • Differentially-pumped vacuum system to 10-5 Torr
    •  

    • Split-flow turbomolecular pump controlling vacuum in three regions
    •  

    • Dual rotary vacuum pump configuration
    •  

    • High-vacuum aluminum analyzer chamber
    Detection System

     

    • Proprietary dual conversion dynode detector
    •  

    • Two off-axis continuous dynode electron multipliers with extended dynamic range
    •  

    • Digital electronic noise discrimination&bulletc1_end; Integrated Divert Valve
    •  

    • &bulletc1_begin;Fully-automated data system control enables user to divert the solvent front, gradient end point and any other portion of the HPLC run to waste
    •  

    • User-definable default state of the valve, either “to waste” or “to source”
    Integrated Syringe Pump

     

    • Syringe Pump allows automated infusion under data system control
    Options

     

    • ESI probe compatible with liquid flowrates of <1μL/min to 1mL/min, without splitting
    •  

    • APCI source compatible with liquid flowrates of 50μL/min to 2mL/min, without splitting
    •  

    • APCI/APPI source compatible with liquid flowrates of 50μL/min to 2mL/min, without splitting
    •  

    • Electron Transfer Dissociation (ETD) enabled
    •  

    • vMALDI™ ion source combines the speed of MALDI with the sensitivity and selectivity of MS/MS
    •  

    • Nanospray source supports static packed tip and dynamic nanospray experiments, compatible with liquid flowrates of 50nL/min† to 2μL/min
    •  

    • Metal needle option for high- and low-flow analyses

    †Lower limit is dependent on gauge of needle used

    Software Features
    Data System

     

    • Xcalibur processing and instrument control software
    •  

    • LCQUAN™ 2.5 quantification package
    •  

    • Microsoft™ Office XP software package
    •  

    • Microsoft Windows™ XP operating system
    •  

    • High-performance PC with Intel™ Pentium™ microprocessor
    •  

    • High-resolution LCD color monitor
    Scan Functions

     

    • Full-scan mass spectra for sensitive analyses and rapid screening of unknown compounds
    •  

    • Selected Ion Monitoring (SIM) for selected ions for target compound analysis
    •  

    • Full-scan product ion spectra at sensitivities higher than any ion trap mass spectrometer
    •  

    • Selected Reaction Monitoring (SRM) for a traditional LC/MS/MS quantitative analytical experiment
    •  

    • MSn for multi-stage MS experiments to probe the structure of ions
    •  

    • ZoomScan- a high-resolution, full-range scan to resolve isotopic envelopes often used for charge state determination of peptides and ionization state
    • determination of organometallics

       

    • Ultra ZoomScan for ultimate resolution
    •  

    • TurboScan™, an ultra-fast scan to improve signal-to-noise and sampling rate
    Exclusive Technologies

     

    • Pulsed Q Collision Induced Dissociation (PQD) enables trapping of low mass fragment ions
    •  

    • Electron Transfer Dissociation (ETD) enabled capability delivers peptide sequence information not available from conventional methods
    •  

    • High Resolution Isolation (HRI) allows for the separation of an isobaric interfering species down to 0.3 Da or for isolation of a thermally labile compound
    •  

    • Unique, proprietary Automatic Gain Control (AGC™) ensures that the ion trap is always filled with the optimum number of ions for any scan type
    •  

    • Dynamic Exclusion™ allows acquisition of MS/MS and MSn spectra from lower intensity ion species
    •  

    • WideBand Activation™ generates more structurally informative spectra Normalized Collision Energy™ compensates for the mass-dependent energy deposition characteristics of ion trap mass spectrometers in MS/MS experiments, providing reproducible data from instrument to instrument
    •  

    • Stepped Normalized Collision Energy allows for the variation of the collision energies in an experiment
    •  

    • Multistage Activation generates combination MS/MS spectra and MS3 spectra based on a user defined neutral loss
    Advanced Data Dependent Experiments

     

    • Data Dependent features trigger acquisition of MSn spectra only when a compound of interest is detected
    •  

    • Isotopic Data Dependent scanning software triggers MS/MS scanning only when a specified isotopic pattern is detected
    •  

    • Triple Play determines the charge state and MS/MS scan range of a multiply charged ion
    •  

    • Nth Order Triple Play allows the number of ions undergoing a Triple Play to be defined
    •  

    • Data Dependent Neutral Loss (NL) MS3 triggers MS3 scan only on the MS/MS product ions with the pre-defined neutral loss to identify and characterize metabolites and post-translational modifications
    •  

    • Ion Mapping™ automatically generates a 3-dimensional MS/MS map, yielding product ion, precursor ion, and neutral loss information
    •  

    • Ion Mapping Browser Software displays data generated by Ion Mapping experiments
    •  

    • Data Dependent Ion Tree performs MSn experiments on up to 25 species
    •  

    • Data Dependent Zoom Map generates sequential MS/MS experiments using a ZoomScan for charge state determination prior to each MS/MS experiment
    •  

    • MSn Browser software displays data generated by Data Dependent Ion Tree and Ion Mapping experiments
    Optional Application-Specific Software

     

    • MetWorks™ automated metabolite identification using spectral trees
    •  

    • Mass Frontier™ spectral interpretation and classification software to identify unknowns
    •  

    • PEAKS powerful, easy de novo sequencing
    •  

    • ProMass™ Deconvolution intact protein analysis
    •  

    • SIEVE™ automated label-free differential expression of proteins and peptides
    •  

    • ProSight PC™ top-down protein identification
    System Specifications

    MS/MS Sensitivity

    Electrospray Ionization (ESI) A loop injection of 2μL of a 125fg/μL solution of reserpine (250 femtograms total sample) at a flow of 400μL/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165 to 615. Atmospheric Pressure Chemical

    Ionization (APCI) A loop injection of 2μL of a 125fg/μL solution of reserpine (250 femtograms total sample) at a flow of 400μL/min of 50% isopropyl alcohol/50% water will produce a minimum signal-to-noise ratio of 100:1, for the transition of the isolated protonated molecular ion at m/z 609 to the largest two product ions, 397 and 448, when the mass spectrometer is operated at unit resolution in the fullscan MS/MS mode, scanning the product ion spectrum from m/z 165 to 615. MSn Sensitivity

    Electrospray Ionization (ESI):

    A loop injection of 2μL of a 125 fg/μL solution of reserpine (250 femtograms total sample) at a flow of 400μL/min of 50% isopropanol/50% water will produce a minimum signal-to-noise ratio of 25:1, for the transition of the unit isolated protonated molecular ion at m/z 609 to the product ion at m/z 397 which is further fragmented to the product ion at m/z 365, when the mass spectrometer is operated at unit resolution in the full-scan MS/MS mode, scanning the product ion spectrum from m/z 165-615.

    Installation Requirements

    Power

     

    • 230VAC ±10.0%, 50/60Hz, 15A, single-phase, earth-grounded supply dedicated to the instrument
    •  

    • 120 or 230VAC single-phase, earth-grounded supply for the data system

    Gas

     

    • One high-purity (99% pure, flowrate 15L/min) nitrogen gas supply for the API source
    •  

    • One ultra-high-purity helium gas supply (99.998% pure) with <1ppm each of water, oxygen, and total hydrocarbons for the mass analyzer

    Environment

     

    • System averages 2300w (8000 BTU/hr.) output when considering air conditioning needs
    •  

    • Operating environment must be 15° to 27°C (59° to 80°F) and relative humidity must be 40 to 80% with no condensation
    •  

    • Optimum operating temperature is 18° to 21°C (65° to 70°F)
    Product References:

    Learn more about accelerating your analysis with the perfect partner for mass spectrometry instruments, Accela™ High-Speed LC System—HPLC and U-HPLC in one system!

    Read More...

    More structural information

    Multiple dissociation techniques, CID, PQD, and optional ETD, expand the amount of structural information that can be recovered from peptides, proteins, and other biological samples.