Description
Quantity
211100
2111LL Sodium Analyzer Electronics Assembly
Full specifications
Description 2111LL Sodium Analyzer Electronics Assembly
Accuracy ±5% or 0.01ppb – whichever is greater
Resolution 1; 2; 3; or 4 significant digits
Response Time 95% within 2 minutes
Voltage 85 to 132V (100mA); 170 to 264V (200mA)
Weight (English) 50 lb.
Weight (Metric) 22.7 g
Flow Rate 40 mL/min.
Sample Temperature 5 to 45 °C
Hertz 50/60Hz
Max. Relative Humidity 211100
Outputs 2 selectable galvanically isolated at either 0-20mA or 4-20mA, 3 - Relay outputs
Temperature (Metric) Operating 5 to 45°C
Inlet Pressure 8 to 100 psig
Range 0.001ppb to 10ppm
Item Description 2111LL Analyzer Only

Please add a quantity

    Please wait, while adding to cart

    Invalid Catalog Number, try after few minutes

    Unable to connect to commerce server, try after a few

    2111LL
    2111LL Low Level Sodium Analyzer
    Full specifications
    Description 2111LL Low Level Sodium Analyzer
    Accuracy ±5% or 0.01 ppb, whichever is greater
    Resolution 1; 2; 3; or 4 significant digits
    Response Time 95% within 2 minutes of injecting a standard solution
    Voltage 85 to 132VAC; 170 to 264VAC
    Height (English) 26 in.
    Height (Metric) 65cm
    Length (English) 11 in.
    Length (Metric) 27cm
    Width (English) 17 in.
    Width (Metric) 45cm
    Weight (English) 50 lb.
    Weight (Metric) 22.7g
    Calibration Double Known Addition
    Enclosure Rating Waterproof; IP66; NEMA 4X
    Flow Rate 40mL/min.
    Sample Temperature 5 to 45°C
    Channels 1
    Communication Details Modbus with Additional Module
    Current Loops 2
    Display Type Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
    Hertz 0 to 60Hz
    Keypad Type Membrane
    Max. Relative Humidity 5 to 95, non-condensing %
    Mounting Options Wall mount
    Options for Channel 1 Sodium
    Options for Channel 2 Optional ph/ORP or Conductivity
    Outputs 0 to 20mA; 4 to 20mA
    Relay Details 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
    Temperature (Metric) Operating 5° to 35°C
    Accuracy (mV) ± (0.5 mV + 0.1%)
    Accuracy (Temperature) ±0.5°C
    Alarm Output 3
    Amperage 5A
    Analog Outputs 2, Galvanically Isolated
    Case Material Valox 364
    Certifications/Compliance CE, CSA, UL, FCC Class A limits
    Includes 2111LL sodium analyzer with sodium electrode, reference electrode, ATC probe, sodium calibration standards kit, CD user guide and options kit
    Inlet Pressure 8 to 100psig
    Measurement Ranges 0 to 10ppm
    Range 0.001ppb to 10ppm
    Sample Inlet 1/4 in. NPTF tube fitting
    Sample Streams 1
    Item Description Instrument Only Package
    Dimensions (L x W x H) 11 x 17 x 26 in. (27 x 45 x 65cm)

    Please add a quantity

      Please wait, while adding to cart

      Invalid Catalog Number, try after few minutes

      Unable to connect to commerce server, try after a few

      2111LLEN
      2111LL Low Level Sodium Analyzer With Enclosure
      Full specifications
      Description 2111LL Low Level Sodium Analyzer With Enclosure
      Accuracy ±5% or 0.01 ppb, whichever is greater
      Resolution 1; 2; 3; or 4 significant digits
      Response Time 95% within 2 minutes of injecting a standard solution
      Voltage 85 to 132VAC; 170 to 264VAC
      Height (English) 26 in.
      Height (Metric) 65cm
      Length (English) 11 in.
      Length (Metric) 27cm
      Width (English) 17 in.
      Width (Metric) 45cm
      Weight (English) 50 lb.
      Weight (Metric) 22.7g
      Calibration Double Known Addition
      Enclosure Rating Waterproof; IP66; NEMA 4X
      Flow Rate 40mL/min.
      Sample Temperature 5 to 45°C
      Channels 1
      Communication Details Modbus with Additional Module
      Current Loops 2
      Display Type Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
      Hertz 0 to 60Hz
      Keypad Type Membrane
      Max. Relative Humidity 5 to 95, non-condensing %
      Mounting Options Wall mount
      Options for Channel 1 Sodium
      Options for Channel 2 Optional ph/ORP or Conductivity
      Outputs 0 to 20mA; 4 to 20mA
      Relay Details 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
      Temperature (Metric) Operating 5° to 35°C
      Accuracy (mV) ± (0.5 mV + 0.1%)
      Accuracy (Temperature) ±0.5°C
      Alarm Output 3
      Amperage 5A
      Analog Outputs 2, Galvanically Isolated
      Case Material Valox 364
      Certifications/Compliance CE, CSA, UL, FCC Class A limits
      Includes 2111LL sodium analyzer with sodium electrode, reference electrode, ATC probe, sodium calibration standards kit, CD user guide and options kit
      Inlet Pressure 8 to 100psig
      Measurement Ranges 0 to 10ppm
      Range 0.001ppb to 10ppm
      Sample Inlet 1/4 in. NPTF tube fitting
      Sample Streams 1
      Item Description With Protective Enclosure Package
      Dimensions (L x W x H) 11 x 17 x 26 in. (27 x 45 x 65cm)

      Please add a quantity

        Please wait, while adding to cart

        Invalid Catalog Number, try after few minutes

        Unable to connect to commerce server, try after a few

        2111LLENG
        2111LL Low Level Sodium Analyzer With Enclosure and Grab Sampler
        Full specifications
        Description 2111LL Low Level Sodium Analyzer With Enclosure and Grab Sampler
        Accuracy ±5% or 0.01 ppb, whichever is greater
        Resolution 1; 2; 3; or 4 significant digits
        Response Time 95% within 2 minutes of injecting a standard solution
        Voltage 85 to 132VAC; 170 to 264VAC
        Height (English) 26 in.
        Height (Metric) 65cm
        Length (English) 11 in.
        Length (Metric) 27cm
        Width (English) 17 in.
        Width (Metric) 45cm
        Weight (English) 50 lb.
        Weight (Metric) 22.7g
        Calibration Double Known Addition
        Enclosure Rating Waterproof; IP66; NEMA 4X
        Flow Rate 40mL/min.
        Sample Temperature 5 to 45°C
        Channels 1
        Communication Details Modbus with Additional Module
        Current Loops 2
        Display Type Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
        Hertz 0 to 60Hz
        Keypad Type Membrane
        Max. Relative Humidity 5 to 95, non-condensing %
        Mounting Options Wall mount
        Options for Channel 1 Sodium
        Options for Channel 2 Optional ph/ORP or Conductivity
        Outputs 0 to 20mA; 4 to 20mA
        Relay Details 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
        Temperature (Metric) Operating 5° to 35°C
        Accuracy (mV) ± (0.5 mV + 0.1%)
        Accuracy (Temperature) ±0.5°C
        Alarm Output 3
        Amperage 5A
        Analog Outputs 2, Galvanically Isolated
        Case Material Valox 364
        Certifications/Compliance CE, CSA, UL, FCC Class A limits
        Includes 2111LL sodium analyzer with sodium electrode, reference electrode, ATC probe, sodium calibration standards kit, CD user guide and options kit
        Inlet Pressure 8 to 100psig
        Measurement Ranges 0 to 10ppm
        Range 0.001ppb to 10ppm
        Sample Inlet 1/4 in. NPTF tube fitting
        Sample Streams 1
        Item Description With Grab Sampler and Enclosure Package
        Dimensions (L x W x H) 11 x 17 x 26 in. (27 x 45 x 65cm)

        Please add a quantity

          Please wait, while adding to cart

          Invalid Catalog Number, try after few minutes

          Unable to connect to commerce server, try after a few

          2111LLG
          2111LL Low Level Sodium Analyzer and Grab Sampler
          Full specifications
          Description 2111LL Low Level Sodium Analyzer and Grab Sampler
          Accuracy ±5% or 0.01 ppb, whichever is greater
          Resolution 1; 2; 3; or 4 significant digits
          Response Time 95% within 2 minutes of injecting a standard solution
          Voltage 85 to 132VAC; 170 to 264VAC
          Height (English) 26 in.
          Height (Metric) 65cm
          Length (English) 11 in.
          Length (Metric) 27cm
          Width (English) 17 in.
          Width (Metric) 45cm
          Weight (English) 50 lb.
          Weight (Metric) 22.7g
          Calibration Double Known Addition
          Enclosure Rating Waterproof; IP66; NEMA 4X
          Flow Rate 40mL/min.
          Sample Temperature 5 to 45°C
          Channels 1
          Communication Details Modbus with Additional Module
          Current Loops 2
          Display Type Custom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
          Hertz 0 to 60Hz
          Keypad Type Membrane
          Max. Relative Humidity 5 to 95, non-condensing %
          Mounting Options Wall mount
          Options for Channel 1 Sodium
          Options for Channel 2 Optional ph/ORP or Conductivity
          Outputs 0 to 20mA; 4 to 20mA
          Relay Details 3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
          Temperature (Metric) Operating 5° to 35°C
          Accuracy (mV) ± (0.5 mV + 0.1%)
          Accuracy (Temperature) ±0.5°C
          Alarm Output 3
          Amperage 5A
          Analog Outputs 2, Galvanically Isolated
          Case Material Valox 364
          Certifications/Compliance CE, CSA, UL, FCC Class A limits
          Includes 2111LL sodium analyzer with grab sampler, sodium electrode, reference electrode, ATC probe, sodium calibration standards kit, CD user guide and options kit
          Inlet Pressure 8 to 100psig
          Measurement Ranges 0 to 10ppm
          Range 0.001ppb to 10ppm
          Sample Inlet 1/4 in. NPTF tube fitting
          Sample Streams 1
          Item Description With Grab Sampler Package
          Dimensions (L x W x H) 11 x 17 x 26 in. (27 x 45 x 65cm)

          Please add a quantity

            Please wait, while adding to cart

            Invalid Catalog Number, try after few minutes

            Unable to connect to commerce server, try after a few

            Product Description

            Features:

            • Resistant to drift with Orion™ Ross™ UltraTM electrode technology
            • Reduces hazardous waste
            • Easy to read backlit display for measurement visibility from a distance
            • No moving parts with the pum-less passive diffusion reagent system
            • Rapid response to changes and ultra low level detection with proprietary flow cell

            Ordering information:

            • All low level sodium monitors come with step-by-step instructions for quick installation and start-up.
            • Available in several configurations including the analyzer instrument only or with a protective enclosure.

            Read More...
             
            Additional resources

            We are continuously improving our website. While we work to include all support materials in one location, you’ll find the following information here:

            Showing of resources

            No Resources Found

            • All Resources ()

            Certificates

            No Certificates found

            tab 4