Close

TRACE™ Ultra Gas Chromatograph

Your lab's analytical requirements are changing all the time. Here's a GC that can keep you a step ahead: the Thermo Scientific™ TRACE™ Ultra Gas Chromatograph. Configured with up to two injectors and three detectors, this multi-channel instrument combines the reliability of the TRACE platform with ultra performance and automation. The result is unmatched productivity, versatility and reliability—plus the sensitivity you need for the most critical GC and GC-MS applications.

Contact Sales

Contact Support

Submit a contact request
Showing 5 7 of 7 Products |
Catalog #
Item Description
Quantity
THERMCOND
Thermal Conductivity Detector
Full specifications
Detector Type Conductivity
Linearity 10^6
Item Description Thermal Conductivity Detector

Please add a quantity

    Please wait, while adding to cart

    Invalid Catalog Number, try after few minutes

    Unable to connect to commerce server, try after a few

    ECAPTURE
    Electron Capture Detector
    Full specifications
    Detector Type Electron Capture
    Cell Body 63Ni source, micro cell volume design
    Linearity >104
    Item Description Electron Capture Detector

    Please add a quantity

      Please wait, while adding to cart

      Invalid Catalog Number, try after few minutes

      Unable to connect to commerce server, try after a few

      PULSEDDC
      Pulsed Discharge Detector
      Full specifications
      Detector Type Pulsed Discharge
      Linearity <10°C
      Item Description Pulsed Discharge Detector

      Please add a quantity

        Please wait, while adding to cart

        Invalid Catalog Number, try after few minutes

        Unable to connect to commerce server, try after a few

        FLAMEION
        Flame Ionization Detector
        Full specifications
        Detection Mode Flame Ionization
        Detector Type Flame Ionization
        Linearity <10°C
        Item Description Flame Ionization Detector

        Please add a quantity

          Please wait, while adding to cart

          Invalid Catalog Number, try after few minutes

          Unable to connect to commerce server, try after a few

          NPHOSPHO
          Nitrogen Phosphorus Detector
          Full specifications
          Detector Type Nitrogen Phosphorus
          Linearity >104
          Item Description Nitrogen Phosphorus Detector

          Please add a quantity

            Please wait, while adding to cart

            Invalid Catalog Number, try after few minutes

            Unable to connect to commerce server, try after a few

            PHOTOION
            Photoionization Detector
            Full specifications
            Detector Type Photo Ionization
            Linearity >104
            Item Description Photoionization Detector

            Please add a quantity

              Please wait, while adding to cart

              Invalid Catalog Number, try after few minutes

              Unable to connect to commerce server, try after a few

              FLAMEPHOTO
              Flame Photometric Detector
              Full specifications
              Detector Type Flame Photometric
              Item Description Flame Photometric Detector

              Please add a quantity

                Please wait, while adding to cart

                Invalid Catalog Number, try after few minutes

                Unable to connect to commerce server, try after a few

                Product Description

                The TRACE GC Ultra system offers a full range of proprietary inlets and easily interchanged detectors to help you solve the most challenging separation problems, or to take speed and throughput to a whole new level.

                Ultra Analytical Performance

                • Direct Column Heating Technology lets you perform analyses in 1 to 2 minutes and shorten analysis cycle times by up to a factor of 35—without compromising analytical resolution, precision or reliability
                • Multidimensional GC (GCxGC) technology extends your separating power for complex sample characterization
                • Large Volume Injection (LVI) techniques boost sensitivity for trace analysis—without additional investment, training or revalidation; 450μL capability available for on-column and PTV inlets
                • Ensure superior retention time control, repeatability and reproducibility with digital pneumatics modules and proprietary column characterization algorithm
                Ultra Versatility
                • Select from a complete range of injectors, including BEST PTV, cold on-column inlets
                • Change detectors in minutes or use up to three stacked or parallel simultaneous detectors to enhance selectivity
                • Choose any stationary phase using a range of column modules
                • Configure up to four heated and two unheated gas valves, eight pressure regulators and needle valves, in/out ports, and packed and capillary columns using an independently heated valve housing
                Ultra Reliability
                • Keep high-boiling contaminants out of the column and reduce maintenance requirements with injector-integrated backflush
                • Operate unattended 24/7; automate your entire workflow with a full range of sample handling options
                • Take GC control and diagnostics beyond the lab with Local Area Networking (LAN) interfacing
                • Streamline data analysis and improve efficiency with Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System, Thermo Scientific™ Chrom-Quest™ software or Thermo Scientific™ Chrom-Card™ data system
                • Select turnkey analyzers for chemical and petrochemical applications, even those requiring advanced, multidimensional column switching techniques
                Choice of Detectors
                • Flame Ionization (FID)
                • Thermal Conductivity (TCD)
                • Electron Capture (ECD)
                • Nitrogen Phosphorus (NPD)
                • Flame Photometric (FPD)
                • Photo Ionization (PID)
                • Pulsed Discharge (PDD)
                Compatible With
                • Thermo Scientific AI/AS 1310 3000 II Liquid Sampling Automation
                • Thermo Scientific™ TriPlus™ RSH Autosampler, TriPlus 300 Headspace Autosampler, TriPlus Autosampler, TriPlus HS Headspace Autosampler, TriPlus Duo Liquid and Headspace Autosampler, TriPlus SPME Automated Sample Preparation
                • Thermo Scientific™ ISQ™ Single Quadrupole GC-MS
                • Thermo Scientific™ ITQ™ GC-Ion Trap MS systems
                • Thermo Scientific™ TSQ Quantum XLS™ and Thermo Scientific™ TSQ Quantum XLS Ultra™ Triple-Stage Quadrupole GC-MS systems
                Certifications
                • International Electrotechnical Commission (IEC): 61010-1:2001
                • EuroNorm (EN): 61010-1:2001
                • Electromagnetic Compatibility (EMC) and Radio Frequency Interference (RFI): CISPR 11/EN 55011: Group 1 Class A and IEC/EN 61326-1:2006

                Read More...