Enhanced Trace Level CO Analyzer, Model 48i-TLE ­ Thermo Scientific

false
/ThermoScientific/
-1

Enhanced Trace Level CO Analyzer, Model 48i-TLE

Thermo Scientific* Model 48i-TLE is a gas filter correlation analyzer with enhanced communication capabilities for ambient air and source emissions monitoring.
The enhanced sample conditioned temperature stabilization and auto-zeroing of the Model 48i-TLE result in a low detection limit for the measurement of Carbon Monoxide.
 
 
 
 
Part Number Description   Quantity
48i-TLE Model 48i-TLE
Request Quote
Please Note: Availability may vary by country.  
 
Using gas filter correlation technology, the Model 48i-TLE measures the amount of carbon monoxide in the air. The Model 48i-TLE is based on the principle that carbon monoxide (CO) absorbs infrared radiation at a wavelength of 4.6 microns. Because infrared absorption is a nonlinear measurement technique, it is necessary for the instrument electronics to transform the basic analyzer signal into a linear output. Instrument uses an exact calibration curve to accurately linearize the instrument output over any range up to a concentration of 1000ppm.
  • Gas filter correlation technology
  • Standard dual range and auto ranges
  • Self aligning optics
  • Temperature and pressure correction
  • User settable alarm levels for concentration
iSeries Advantage:

  • Ethernet connectivity for efficient remote access
  • Enhanced user interface with one button programming and large display screen
  • Flash memory for increased data storage and user downloadable software
  • Enhanced electronics design optimizes product commonality
  • Improved layout for easier accessibility to components

Ordering Alerts: Choose from the following configurations/options to customize:

Voltage options

A:120VAC 50/60Hz

B: 220VAC 50/60Hz

J: 100VAC 50/60Hz

Internal zero/span

C: Internal zero / span valves w/zero air scrubber

Filter Wheel Purge

P: Filter wheel purge set-up

Optional I/O

A: No optional I/O (standard)

C: 0-20, 4-20mA current output - 6 channels, 0-10V analog input - 8 channels

Mounting hardware

A: Bench mounting (standard)

B: Ears and handles, EIA

C: Ears and handles, retrofit


Compliance: ETL, CSA, UL, CE


Certifications: USEPA (RFCA-0981-054), Pattern Approval (China)
Specifications for 48i-TLE Enhanced Trace Level CO Analyzer
Measurement RangesPreset Ranges: 0-1, 5, 10, 20, 50, 100, 200, 500, 1000ppm

0-1, 2, 5, 10, 20, 50, 100, 200, 500, 1000mg/m3

Custom Ranges: 0-1 to 1000ppm

0-1 to 1000mg/m3

Flowrate0.5 L/min
Min. Detection Limit0.04ppm (30 second averaging time)
Linearity± 1% full scale
Response Time60 seconds (30 second averaging time)
Zero Noise0.02ppm RMS (30 second averaging time)
DriftZero Drift (24 hour): < 0.1ppm

Span Drift (24 hour): ± 1% full scale

Input OutputOutputs: Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard).

0-20 or 4-20mA Isolated Current Output (optional)

Inputs: 16 Digital Inputs (standard), 8 0-10V Analog Inputs (optional)

MountingBench, EIA, retrofit
Power Requirements100VAC, 115VAC, 220-240VAC ±10% @ 300w
Temperature Range [Operating]5° to 40°C (41° to 104°F)
DimensionsD x W x H: 23 x 16.75 x 8.62 in. (584 x 425 x 219mm)
Weight55 lb. (25 kg)

Cat. No.Description
48i-TLEModel 48i-TLE
 
 
 
 
 
Help image

Need Help?


Have a Question?
We're here to help you.

Select Country for Contact Info This website provides global contact information for our products and services. When you select a Contact Country, the contact information that is displayed by default will be for this country.