Multigas Calibrator, Model 146i ­ Thermo Scientific

false
/ThermoScientific/
-1

Multigas Calibrator, Model 146i

The Thermo Scientific* Model 146i generates gas standards for the calibration of ambient air and other gas monitoring instrumentation.
The output of the Model 146i is used to calibrate instruments that perform zero, precision, Level 1 span checks, audits, and multi-point routines in accordance with USEPA requirements.
 
 
 
 
Part Number Description   Quantity
146i Model 146i Multigas calibrator
Request Quote
Please Note: Availability may vary by country.  
 
The Thermo Scientific* Model 146i multi-gas calibrator supplies precise levels of ozone, carbon monoxide, non-methane hydrocarbons, sulfur dioxide, nitric oxide and nitrogen dioxide or other gases that a user may require.
Key Features:

  • Mass flow controllers dilute standard gases for the calibration of gas monitoring instrumentation
  • Multiple calibration routines can be stored in calibrator memory
  • Microprocessor-based calculation increases operator availability
  • Unit can be operated remotely by a data logger or to perform multipoint calibrations
  • Gas Phase Titration for Generation of O3 and NO2
Ozone Generator Option

  • Maximum output: 1ppm at 6 SLPM
  • Minimum output: 10ppb at 6 SLPM

Photometer System

  • Full scale range: 100ppb to 5ppm user selectable
  • Linearity: 1% of full scale
  • Precision: 1ppb
  • Response time: 180 seconds to 95% of target
  • Minimum detectable limit: 3 ppb

iSeries Advantage:

  • Ethernet connectivity for efficient remote access
  • Enhanced user interface with one button programming and large display screen
  • Flash memory for increased data storage and user downloadable software
  • Enhanced electronics design optimizes product commonality
  • Improved layout for easier accessibility to components

Ordering Alerts: Voltage options

A: 120VAC 50/60Hz (standard)

B: 220VAC 50/60Hz

J: 100VAC 50/60Hz

Calibration Sources

N: No Optional Calibration Sources (standard)

P: Internal Permeation Span Source

T: Gas Phase Titration

B: Gas Phase Titration with Photometer

C: Internal Permeation Span Source with Gas Phase Titration

D: Internal Permeation Span Source with Gas Phase Titration and Photometer

Span Ports

3: Three Span Inputs (standard)

6: Six Span Inputs

Span Gas Mass Flow Controller

A: 50 SCCM

B: 100 SCCM (standard)

C: 200 SCCM

Zero Gas Mass Flow Controller

D: 5 SLPM

E: 10 SLPM (standard)

F: 20 SLPM

Optional I/O

A: None (standard)

C: I/O expansion board (4 to 20mA outputs - 6 channels, 0-10V inputs - 8 channels)

Mounting Hardware

A: Bench mounting (standard)

B: Ears and handles, EIA

C: Ears and handles, Retrofit


Compliance: � ETL, CSA, UL, CE

Certifications: � Pattern Approval (China)
Specifications for Model 146i Multigas Calibrator
FlowrateFlow range of dilution air 0 to 10 SLPM; optional ranges 0 to 5/0 to 20 SLPM

Flow range of cylinder gases 0 to 100SCCM; optional ranges 0 to 50/0 to 200 SCCM

Zero Air requirements 10 SLPM at 30psi; optional ranges 20 SLPM at 30psi

Accuracy (of dilution system flow control)± 2%of reading or 1% of full-scale, whichever is less (20 to 100% full scale)
Repeatability (of flow control)±0.2% FS (Porter flow controller spec-better than 146C)
Linearity (of mass flow measurements)1% of full scale
Response Time (of dilution system)less than 60 seconds to 99% of target (146C spec)
Input OutputTest Channel Analog: 6 at ±100mV, 1,5,10V (user selectable); Input: 16 digital control inputs; Output: 10 relay and eight 24VDC Solenoid
Power Requirements100VAC 50/60Hz, 115VAC 50/60Hz, 220 to 240VAC 50/60Hz, 275w
MountingBench mounting (standard), EIA, Retrofit
Operating Limits [Temperature Range]0° to 40°C
DimensionsD x W x H: 23 x16.75 x8.62 in. (584.19 x 425.45 x 218.94mm)
Weight51 lb. (58 lb. for 220-240VAC)

Cat. No.Description
146iModel 146i Multigas calibrator
 
 
 
 
 
Help image

Need Help?


Have a Question?
We're here to help you.

Select Country for Contact Info This website provides global contact information for our products and services. When you select a Contact Country, the contact information that is displayed by default will be for this country.



  • Sales
  • Service
 